Process Calibrator -

CPH6000


Applications

  • Calibration and service companies
  • Maintenance facilities
  • Control and instrumentation workshops
  • Quality assurance

Key Features

  • DigitalConsole incorporating easily interchangeable pressure sensor (Sensors can optionally be remotely mounted)
  • Measuring range: 0 ... 250 mbar to 0 ... 6,000 bar
  • Certified accuracy up to 0.025 % (Calibration Certificate incl.)
  • CALIBRATION and PRESSURE-SWITCH TEST functions
  • PC software and complete service sets (incl. pressure generators) available

Process Calibrator -

CPH6000

Description

 

Applications

In order to provide an optimal solution for each application, a wide variety of pressure sensors are available. With an accuracy of 0.025% and pressure ranges up to 1,000 bar, all are quickly and easily interchangeable without the need for additional tools. In addition to being mounted on the instrument, the pressure sensor can also be mounted remotely using an extension cable (approximately 1 m long). If the pressure sensor is changed, the instrument automatically recognises the new measuring range and thus the operator does not need to reconfigure it manually.

Functionality

In the set-up menu there are three operating modes to choose from: MEASURING / CALIBRATION and PRESSURE-SWITCH TEST. In the CALIBRATION and PRESSURE-SWITCH TEST modes respectively, calibration data for several calibrations can be stored or the switching hysteresis can be automatically determined, with the help of a menu assistant. The electrical and signal connections for the test devices are pro-tected against rough conditions in the field by captive rubber covers.

Software

For evaluating and documenting the calibration data stored in the CPH6000, two PC programs are available. By using PrintCal software (based on EXCEL), the data can be transferred automatically into a printable calibration certificate. While EasyCal software, in addition to offering PC-driven calibration, also allows the administration of calibration and instrument data within an ACCESS database. For data transfer from the instrument, both an RS-232 and a USB interface are available.

Complete service and test sets

Various configurations of fully equipped service cases are available for maintenance and service applications. Service cases are available with pressure generating equipment, battery charging unit, measuring cable set, pressure-connector adapters, etc..

Certified accuracy

For each pressure transmitter the accuracy is certified and a factory calibration certificate accompanies the equipment. If required, we will also happily provide a DKD calibration certificate for the equipment, issued from our in-house DKD laboratory.