Pressure Verification System
Applications
- Wind tunnel pressure verification
- Temperature probe secured near the transducers to allow the transducer temperature to be monitored
Special Features
- Contains 5 measurement transducers arranged with a high precision barometric transducer, a single pressure control channel, and 3 dual transducer high line pressure differential transducers
- Dual transducers have accuracies of 0.009% IS-50 on the absolute side and 0.010% of full scale on the differential side
- Instrument software provides multi-speed reading rates and optional reading synchronization for the 3 dual transducers
Description
The Mensor Model 9476 Pressure Verification System is a multi-channel pneumatic measuring and controlling instrument for wind tunnel pressure verification. It contains 5 measurement transducers arranged with a high precision barometric transducer, a single pressure control channel, and 3 dual transducer high line pressure differential transducers.
The barometric transducer can be monitored independently and used as a precision reference to automatically null the readings of the four absolute transducers. The instrument can be operated from the front panel, over a RS-232 serial port or a 10/100/1000 Mbps Ethernet port. The barometric transducer has a range of 8 to 17 psiA with an accuracy of 0.008% of reading. The pressure control transducer has a range of 0 to 33 psiA with an accuracy of 0.010% of full scale. The 3 dual transducers are +/-15 psiD with up to 33 psi line pressure and +/-5 psiD with up to 33 psi line pressure. The dual transducers have accuracies of 0.009% IS-50 on the absolute side and 0.010% of full scale on the differential side. All transducers have a recommended calibration interval of 1 year. All transducers are protected with overpressure relief valves set to approximately 110% of range. Each transducer is removable from the front panel of the instrument. The instrument software provides multi-speed reading rates and optional reading synchronization for the 3 dual transducers. The system also includes a temperature probe secured near the transducers to allow the transducer temperature to be monitored.
The 9476 is housed in an aluminum chassis having dimensions of 17.75” (45.09 cm) wide, 7” (17.78 cm) high, and 17.5” (44.45 cm) deep. Standard rack ears add 1.25 (3.18 cm) to the width and 1.75” (4.45 cm) to the depth. All porting extends from the rear of the chassis and adds additional depth depending on fittings and connections to the unit. The unit is configured for desktop or rack mounting in a standard 19” instrumentation rack and has a 4U height when the chassis feet are removed. The unit operates from universal power (100 to 240 volt 50/60 Hz) at 2 amps maximum. Two thumb screws on the front panel allow access to the removable transducers and the system memory card. The overall system can include as options, a calibration sled for external calibration of the measurement transducers and a transit case for secure shipping.