Service / Calibration

Calibration Service

Mensor provides accredited calibration services for pressure, temperature and mass. The Scope of Accreditation to ISO/IEC 17025 & ANSI/NCSL Z540 shows the full scope and capability of our laboratory.

The best way to communicate your calibration need is to complete and submit the Calibration Quote Request form. This action will immediately send all necessary information to our Customer Service team, who will respond with a price and turnaround time. You can also contact Mensor at 512-396-4200 (extension 257 or wait for the prompt and press 2 for Customer Service) or email techservices@mensor.com to communicate your specific pressure calibration requirements.

Once you are ready to send your instrument in for calibration (or repair), fill out and submit the Product Return form to provide us with instructions.

Traceability

All of our standards are traceable to SI units of measurement through NIST or the equivalent recognized international standards organizations.

Pressure

All pressure sensors drift due to age, mechanical, chemical or thermal stresses. Although this can not be avoided, it can be detected in time through calibration or periodic verification. Use Mensor's A2LA accredited calibration service for your pressure instruments to minimize the risk of drift.

Advantages:

  • Fast turnaround
  • 50+ years of experience in pressure calibration
  • Stay in compliance
  • Avoid recalls

Pressure calibration scope under A2LA accreditation:

Parameters Range Calibration Uncertainties
Gauge, Pneumatic

±18 psig
±2.2 psig
(-15 to 1100) psig
(-15 to 6000) psig

18 ppm psig
30 ppm psig
14 ppm psig
20 ppm psig
Gauge, Hydraulic (0 to 30,003) psig 32 ppm psig
Absolute, Pneumatic (0 to 1100) psia
(0 to 6000) psia
14 ppm psia
21 ppm psia
Absolute, Hydraulic (0 to 30 015) psia 32 ppm psia
Negative Gauge (0 to -15) psig
(0 to -15) psig
21 ppm psig
26 ppm psig

The A2LA Scope of Accreditation to ISO/IEC 17025 and ANSI/NCSL Z540 can be viewed at this link.

Mass

Mass sets are used by deadweight testers to generate precise pressure using the definition: P=F/A. The force (F) in this equation is generated by mass in a gravitational field.  It is important to know the mass precisely to calculate the force.  Mensor's calibration measurement capabilities for mass calibration within the scope of our A2LA accreditation is as follows:

Parameter Range Calibration Measurement Capability (+/-)
Mass (0 to 1) kg
(0 to 10) kg
0.24 mg
2.5 mg

The A2LA Scope of Accreditation to ISO/IEC 17025 and ANSI/NCSL Z540 can be viewed at this link.

Temperature

Precice measurement of temperature is important in many applications and industries.  Mensor's temperature calibration capabilities under our A2LA accreditation are as follows:

Parameter Range Calibration Uncertainty 
Temperature (0 to 50) Degrees C 0.057 Degrees C

The A2LA Scope of Accreditation to ISO/IEC 17025 and ANSI/NCSL Z540 can be viewed at this link.


Pressure and Temperature Units Conversion Utility:


Value Source unit Target unit

Result
Calibration RFQs &
Return Forms

Request a quote for calibration or return a product for calibration or repair

Tech Services Team
Certificates

View our 17025 (A2LA) accreditation and ISO 9001:2015 Certificates