Mensor Corporation provided pressure calibration and test instrumentation, sensors and customized pressure calibration solutions.







Welcome to Mensor...
The Precision Pressure CompanyTM

FAQ's Click to view our new FAQ's page where we will answer Frequently Asked Questions
CPT 6180

Introducing the new CPA 2501 Avionics Digital Pressure Gauge. Single or dual range Altitude and/or Airspeed channels

CPT 6180

Introducing the new CPT 6180 High Precision Pressure Transducer with 0.01%intelliscale-50 uncertainty and
365 day calibration stability.

Since 1969 Mensor Corporation has been designing and manufacturing precision pressure measuring and pressure calibration instruments and systems. From the very first quartz manometer for the aerospace industry, to the modern CPC 6000 Automated Pressure Calibrator today, Mensor, now a part of WIKA Calibration Line, specializes in providing quality pressure products and services to a wide variety of industries around the world.

Products

Mensor products include automated pressure calibrators, digital pressure gauges, portable calibrators, smart pressure transducers, deadweight testers, air data test sets and custom designed pressure test and calibration systems. Complete content of the Mensor Web site can be viewed in the site map.

Calibrators - pressure controlling calibrators / controllers

CPC 3000

CPC 6000 Automated Pressure Calibrator

 

 

CPC 8000

 

CPC 3000
  • High Speed - 3 Second Control
  • 0.025% FS accuracy
  • 5 to 1000 psi

  • CPC 6000 New feature! (Now available with Intelliscale Sensors)
  • two channels
  • two sensors per channel
  • 0.01% IS-50 accuracy
  • 365 day Recommended Cal Interval
  • 0.36 to 1500 psi

  • CPC 8000 X
  • Single channel/dual range
  • 0.008% Intelliscale33 accuracy
  • 2 to 6000 psi

  • CPC 8000 L
  • Single channel/dual range
  • 0.01% FS accuracy
  • 0.36 to 6000 psi

  • CPC 8000 H
  • Single channel
  • 0.01% FS accuracy
  • 8700 to 23,000 psi
  • Pressure Indicators - Digital Pressure Gauges - Portable Pressure Indicators - Handheld Pressure Calibrators

    CPG 2500 Digital Pressure Gauge

     

    CPH 6400 Handheld Pressure Gauge
    CPG 2500
  • Dual range
  • CPA 2501 avionics version
  • 0.01%FS accuracy
  • 0.36 to 10,000 psi.

  • Series 2300
  • Dual range
  • 0.015%FS accuracy
  • 0.36 to 6,000 psi.

  • Series 2400
  • Single range
  • 0.03%FS accuracy
  • 0.36 to 6,000 psi.

  • WIKA CPH 6000, 6200 & 6400
  • Interchangeable Ranges
  • Intrinsically Safe(CPH 62I0)
  • 0.2% to 0.025% FS accuracy
  • Up to 4000 bar (~60,000 psi)
  • Reasons to Choose a Pressure Indicator.

    Digital Pressure Transducers
    Pressure Transducers
    6100
    Model 6180 Digital Pressure Transducer
  • 0.01%IS-50 Accuracy
  • 0-15 to 0-6,000 psi.
  • RS232 or RS485 Comm.

  • Model 6100 Digital Pressure Transducer
  • 0.01% FS Accuracy
  • 0.36 to 6,000 psi.
  • RS232 or RS485 Comm.

  • Model 6000 Digital Pressure Transducer
  • 0.02%FS Accuracy
  • 15 to 6,000 psi.
  • RS232 or RS485 Comm.
  • 316L SS Wetted parts
  • Deadweight Testers - Pressure Balance

    Deadweight tester
    CPB 5000-P, Pneumatic Deadweight Tester
  • 0.01% / 0.008% of reading
  • 1500 psi

  • CPB 5000-H, Hydraulic Deadweight Tester
  • 0.01% / 0.008% of reading
  • 15000 psi

  • CPB 3000, Hydraulic Deadweight Tester
  • 0.025% of reading
  • 15000 psi

  • Line

    Air Data Test Set - ADTS & Avionics Indicator

    Air Data Test Set

    CPA 2501

    Model 8201 Air Data Test Set
  • 0.01% FS pressure accuracy
  • Dual channel altitude & airspeed
  • Altitude rate & airspeed rate

  • CPA 2501 Avionics Digital Indicator
  • Accuracy +/- 3 ft. at sealevel
  • Dual channel Ps and Pt or Qc
  • Altitude and airspeed indication
  • Altitude rate & airspeed rate
  • Custom Pressure Systems
    Rach System
    Precision Pressure Systems
  • Turn key solutions
  • High Volume Pressure Controllers
  • Multi-Channel Pressure Controllers
  • Rack Mounted Systems
  • Cart Mounted Systems
  • Manifolds
  • Pneumatic Controls
  • Wind Tunnel Monitoring
  •  
    EasyCal Calibration Software

    EasyCal

    EasyCal Software Data sheet
  • Calibration certificates
  • Automatically generates cal steps
  • Calibration assistant included
  • Customized test protocols
  • line
     
    Mensor Products
     
       
    line
     
    Contact Mensor
     
     
    Toll Free: 800-984-4200
    Phone: 512-396-4200
    Fax: 512-396-1820
     

    line

    Service with Quality

    Mensor provides world-class service and support for our products. Our Quality Management System is ISO 9001:2008 certified and our calibration laboratory is accredited to ISO 17025:2005.

    Mensor is ISO 9001 CertifiedMensor is accredited to ISO 17025 by A2LA

    Community

    Mensor is an advocate for community participation and is active in both the United Way and the American Heart Association. Mensor is also a charter member of the San Marcos Manufacturers Association (SMMA).

    Mensor supports the United WayMensor supports the American Heart Association
     
    Reasons to Choose a Pressure Controlling Calibrator.
     

    Mensor precision pressure calibrators provide an automated and accurate way to measure and control pressure. These calibrators are sometimes referred to as precision pressure controllers.  The pressure output from a Mensor calibrator is usually connected to a lower accuracy pressure device. This "device under test" (DUT) is then tested or calibrated to verify it's pressure reading accuracy. The DUT can then be adjusted to agree with the more accurate Mensor calibrator.

    Mensor Specializes in precise and accurate pressure devices.  Precision and accuracy in the pressure calibration industry are associated with devices that are used as pressure standards.  Pressure standards provide a pressure reference that is traceable to the National Institute of Standards and Technology.

    Mensor Precision Pressure Calibrators are used in pressure calibration labs or in production environments where automation and efficiency is needed.  Mensor Precision Pressure Calibrators make pressure calibration and production testing more efficient by allowing automation of the process; this is achieved by combining pressure control and pressure measurement within a single device. Remote operation, computer automation, and data acquisition can be achieved using remote communication via IEEE-488, RS-232 or Ethernet connections.

    Back to top

     
    Reasons to Choose a Pressure Indicator.
     

    Mensor Precision Pressure Indicators, also called Digital Pressure Gauges, are appropriate for use when there is a need to measure an external pressure source very accurately. The sensor in the digital pressure gauge measures the pressure, and the indicator displays the pressure in user specified units (psi, bar, ka, inches of mercury etc....). 

    Simply stated, Mensor precision pressure indicators provide an accurate way to measure pressure. The measurement is traceable to the National Institute of Standards and Technology (NIST).  

    Mensor Indicators or Digital Pressure Gauges are used as pressure standards for pressure calibration labs, test facilities or in production environments where a precise pressure indication is needed.

    Back to top

     
    Reasons to Choose a Pressure Transmitter.
     

    Mensor Precision Pressure Transmitters, sometimes called Digital Pressure Transmitters, transducers or just pressure sensors, are appropriate for use when there is a need to measure an external pressure source very accurately but there is no need for local pressure indication.

    The sensor in the Digital Pressure Transmitter measures the pressure and transmits the pressure via RS-232, RS-485 or analog output to a host computer or data acquisition system. Simply stated, Mensor Precision Pressure Transmitters provide an accurate way to measure and transmit a digital or analog signal that represents a measurement of the pressure being sensed. The measurement is traceable to the National Institute of Standards and Technology (NIST).  

    Mensor Transmitters are used in OEM applications to measure pressure in devices that require accurate pressure input. They can also be used as pressure standards for pressure calibration labs, test facilities or in production environments where transmission of a pressure signal is needed.

    Back to top

     
    Reasons to Choose a Deadweight Tester.
     

    Mensor Deadweight Testers also referred to as Pressure Balances are primary pressure standards. This means that they measure pressure directly by applying a Force over an Area; this is the definition of pressure, P=F/A. The force comes from precisely machined masses that are stacked on a precision piston that has a specific cross sectional area. The piston rotates within a cylinder and floats atop a hydraulic (oil) or pneumatic (air) fluid under pressure. This generates a stable pressure that can be applied to a pressure device being tested.

    Deadweight Testers are appropriate for use when there is a need to calibrate a wide range of pressure devices. Because the accuracy is a percent of reading, a skilled operator can use a deadweight tester to calibrate a wide range of pressure devices. Mensor Deadweight testers can have an accuracy as high as 0.008% of reading. The measurement is traceable to the National Institute of Standards and Technology (NIST).

    Deadweight testers do not require a power source which makes them a good choice for remote operation.   Dead weight testers are used as pressure standards in pressure calibration labs, test facilities, and field calibration.

    Back to top

     
    Reasons to Choose an Air Data Test Set
     

    Air Data Test Sets (ADTS) are specialized dual channel pressure calibrators / controllers specifically designed to calibrate altitude (Ps) and Airspeed (Q) indicators or air data computers on aircraft and in avionics laboratories. In addition, the 8201 Air Data Test Set can control altitude rate (vertical airspeed) and air speed rate (acceleration). When there is a need to control, test and calibrate these avionics parameters using a high accuracy standard the 8201 Air Data Test Set is the best choice.

    The new Model CPA 2501 is a dual channel avionics digital indicator that can read altitude, altitude rate, airspeed and airspeed rate. If there is no need to control these parameters internally then the CPC 2501 is the best choice.

    The 8201 Air Data Test Set has been used at military bases, commercial airliners, defense contractors manufacturing aircraft and helicopters, manufacturers of commercial airplanes, helicopters and aircraft components and in avionics test facilities around the world.

    Back to top

     
    Reasons to Choose a Custom System.
     

    A custom system is the right choice if there is a special requirement that standard Mensor controller, indicator or transmitter cannot meet. A custom system may include one or several standard Mensor products integrated into a cart or rack. A Custom system can also be a product that is designed specifically for your requirements. In either case our custom systems department will work to design the right product that will fulfill your specific needs.

    Mensor Custom Systems have been used in the automotive, aerospace, Semiconductor and medical industries, as well as on military bases, and with defense contractors.

    Back to top

         
    replace with your keywords replace with your keywords replace with your keywords replace with your keywords replace with your keywords replace with your keywords replace with your keywords replace with your keywords